Overview

Request 885543 accepted

- Add gasnet-fix-multiple-definitions.patch to fix compatibility with GCC10

- Always use the default openmpi

- Update to GASNet 1.32.0
- Libfabric (ofi-conduit)
- Fix bug 3682: incorrect behavior for non-bulk puts larger than a page
- Compatibility fixes for libfabric version 1.6
- InfiniBand Verbs (ibv-conduit)
- GASNET_DISABLE_MUNMAP now defaults to enabled for ibv-conduit.
- Now use HCA's maximum supported MTU by default, resulting in nearly a 2x
increase in peak Get bandwidth on modern HCAs.
- Fix bug 3339: allow ibv-conduit to operate on Omni-Path hardware.
ofi-conduit and psm-conduit remain the recommended conduits for Omni-Path.
- Portable UDP (udp-conduit)
- Reduce polling cost on single-supernode runs. smp-conduit remains the
recommended conduit for use on single-supernode shared-memory systems.
- Portable MPI (mpi-conduit)
- Reduce polling cost on single-supernode runs. smp-conduit remains the
recommended conduit for use on single-supernode shared-memory systems.
- GASNet tools (spec v1.12)
- Numerous improvements to backtrace support, including fixing the
following bugs:
- Bug 3624: Improve backtrace fail-over behavior
- Bug 3625: call prctl(PR_SET_PTRACER,...) before backtrace on Linux
- Bug 3626: prioritize lldb on Mac OS X
- Bug 3627: unblock the unfreeze signal prior to backtrace
- Bug 3637: Fix EXECINFO backtrace for *BSD
- Enable GDB backtrace on Cray systems, when available
- Bug 3664: GASNETT_PREDICT_{TRUE,FALSE} result value semantics change slightly

Loading...

Request History
Bernhard Wiedemann's avatar

bmwiedemann created request

- Add gasnet-fix-multiple-definitions.patch to fix compatibility with GCC10

- Always use the default openmpi

- Update to GASNet 1.32.0
- Libfabric (ofi-conduit)
- Fix bug 3682: incorrect behavior for non-bulk puts larger than a page
- Compatibility fixes for libfabric version 1.6
- InfiniBand Verbs (ibv-conduit)
- GASNET_DISABLE_MUNMAP now defaults to enabled for ibv-conduit.
- Now use HCA's maximum supported MTU by default, resulting in nearly a 2x
increase in peak Get bandwidth on modern HCAs.
- Fix bug 3339: allow ibv-conduit to operate on Omni-Path hardware.
ofi-conduit and psm-conduit remain the recommended conduits for Omni-Path.
- Portable UDP (udp-conduit)
- Reduce polling cost on single-supernode runs. smp-conduit remains the
recommended conduit for use on single-supernode shared-memory systems.
- Portable MPI (mpi-conduit)
- Reduce polling cost on single-supernode runs. smp-conduit remains the
recommended conduit for use on single-supernode shared-memory systems.
- GASNet tools (spec v1.12)
- Numerous improvements to backtrace support, including fixing the
following bugs:
- Bug 3624: Improve backtrace fail-over behavior
- Bug 3625: call prctl(PR_SET_PTRACER,...) before backtrace on Linux
- Bug 3626: prioritize lldb on Mac OS X
- Bug 3627: unblock the unfreeze signal prior to backtrace
- Bug 3637: Fix EXECINFO backtrace for *BSD
- Enable GDB backtrace on Cray systems, when available
- Bug 3664: GASNETT_PREDICT_{TRUE,FALSE} result value semantics change slightly


Saul Goodman's avatar

licensedigger accepted review

ok


Wolfgang Engel's avatar

bigironman added as a reviewer

Being evaluated by staging project "openSUSE:Backports:SLE-15-SP3:Staging:adi:45"


Wolfgang Engel's avatar

bigironman accepted review

Picked "openSUSE:Backports:SLE-15-SP3:Staging:adi:45"


Nicolas Morey-Chaisemartin's avatar

NMoreyChaisemartin accepted review


Yuchen Lin's avatar

maxlin_factory accepted review

Staging Project openSUSE:Backports:SLE-15-SP3:Staging:adi:45 got accepted.


Yuchen Lin's avatar

maxlin_factory approved review

Staging Project openSUSE:Backports:SLE-15-SP3:Staging:adi:45 got accepted.


Yuchen Lin's avatar

maxlin_factory accepted request

Staging Project openSUSE:Backports:SLE-15-SP3:Staging:adi:45 got accepted.

openSUSE Build Service is sponsored by