Overview
Request 220524 accepted
- Release 1.6.3:
+ Added ProPhoto.icm and ProPhotoLin.icm to ref profiles.
+ Fix bug in xicclu -py conversion.
+ Added code to minimize ICC rounding error on matrix profile
white point accuracy. Re-generated all reference profiles with
this change.
+ Changed i1d3 driver to completely ignore any EEPROM checksum
errors for non "A-01" rev. instruments.
+ Made transplot handle RGB->RGB device link.
+ Removed colprof -y option. Use "profcheck -v2" instead, as it
is more developed.
+ Fixed bug in dispcal - it was not using the final measurement
pass to update the calibration curves.
+ Fixed bug in spotread, dispcal & dispread for CCSS capable
instruments where refresh display types was being ignored if a
custom observer was used, and/or the custom observer as being
ignored, and/or a CCMX was being ignored.
+ Renamed verify to colverify to avoid clash with MSWin program
of the same name. Made it print the patch location for -v2 if
it is present in the file.
+ Changed targen to ensure that -V and -p options effects are
reflected in the resulting expected CIE values of the .ti1
file.
+ Changed targen so that -V parameter also affects single
channel, grey wedge, grid & body centered grid point
distribution.
+ Changed colprof to deal with variable grid distribution in a
more neuanced way, to reduce overshoot artifacts when the -V
parameter is used.
+ Changed colprof to used a power_like function for the grid (forwarded request 220491 from fcrozat)
Request History
kwk created request
- Release 1.6.3:
+ Added ProPhoto.icm and ProPhotoLin.icm to ref profiles.
+ Fix bug in xicclu -py conversion.
+ Added code to minimize ICC rounding error on matrix profile
white point accuracy. Re-generated all reference profiles with
this change.
+ Changed i1d3 driver to completely ignore any EEPROM checksum
errors for non "A-01" rev. instruments.
+ Made transplot handle RGB->RGB device link.
+ Removed colprof -y option. Use "profcheck -v2" instead, as it
is more developed.
+ Fixed bug in dispcal - it was not using the final measurement
pass to update the calibration curves.
+ Fixed bug in spotread, dispcal & dispread for CCSS capable
instruments where refresh display types was being ignored if a
custom observer was used, and/or the custom observer as being
ignored, and/or a CCMX was being ignored.
+ Renamed verify to colverify to avoid clash with MSWin program
of the same name. Made it print the patch location for -v2 if
it is present in the file.
+ Changed targen to ensure that -V and -p options effects are
reflected in the resulting expected CIE values of the .ti1
file.
+ Changed targen so that -V parameter also affects single
channel, grey wedge, grid & body centered grid point
distribution.
+ Changed colprof to deal with variable grid distribution in a
more neuanced way, to reduce overshoot artifacts when the -V
parameter is used.
+ Changed colprof to used a power_like function for the grid (forwarded request 220491 from fcrozat)
factory-auto accepted review
Check script succeeded
factory-auto added a reviewer
Please review sources
factory-auto added a reviewer
Please review build success
factory-auto added a reviewer
Check Staging Project
licensedigger accepted review
{"approve": "preliminary, version number changed"}
factory-repo-checker accepted review
Builds for repo openSUSE_Factory
a_jaeger accepted review
ok
coolo accepted review
ok
coolo approved review
ok
coolo accepted request
checkin