Real-time performance monitoring
netdata is a highly optimized Linux daemon providing real-time performance monitoring for Linux systems, Applications, SNMP devices, over the web!
- Developed at network
- Sources inherited from project openSUSE:Factory
-
5
derived packages
- Download package
-
Checkout Package
osc -A https://api.opensuse.org checkout openSUSE:Factory:zSystems/netdata && cd $_
- Create Badge
Refresh
Refresh
Source Files
Filename | Size | Changed |
---|---|---|
netdata-logrotate-su.patch | 0000000252 252 Bytes | |
netdata-rpmlintrc | 0000000095 95 Bytes | |
netdata-smartd-log-path.patch | 0000000660 660 Bytes | |
netdata-v1.16.0.tar.gz | 0003768089 3.59 MB | |
netdata.changes | 0000055473 54.2 KB | |
netdata.spec | 0000005108 4.99 KB |
Revision 11 (latest revision is 52)
Dominique Leuenberger (dimstar_suse)
accepted
request 714120
from
Mia Herkt (lachs0r)
(revision 11)
- Update to v1.16.0 Improvements: * Health: + Easily disable alarms, by persisting the silencers configuration + Repeating alarm notifications + Simplified the health cmdapi tester - no setup/cleanup needed + Αdd last_collected alarm to the x509check collector + New alarm for abnormally high number of active processes. * Security: + SSL support in the web server and streaming/replication + Support encrypted connections to OpenTSDB backends * New collectors: + Go.d collector modules for WMI, Dnsmasq DHCP leases and Pihole + Riak KV instances collector + CPU performance statistics using Performance Monitoring Units via the perf_event_open() system call. (perf plugin) * Collector improvements: + Handle different sensor IDs for the same element in the freeipmi plugin + Increase the cpu_limit chart precision in cgroup plugin + Added userstats and deadlocks charts to the python mysql collector + Add perforce server process monitoring to the apps plugin * Backends: + Prometheus remote write backend * DB engine improvements: + Reduced memory requirements by 40-50% + Reduced the number of pages needed to be stored and indexed when using memory mode = dbengine, by adding empty page detection * Rebranding: + Updated the netdata logo and changed links to point to the new website * Other: + Pass the the cloud base url parameter to the notifications mechanism, so that modifications to the configuration are respected when creating the link to the alarm + Improved logging, to be able to trace the CRITICAL: main[main] SIGPIPE received. error Bug fixes: * Fixed ram_available alarm * Stop monitoring /dev and /run in the disk space and inode usage charts * Fixed the monitoring of the “time” group of processes * Fixed compilation error PERF_COUNT_HW_REF_CPU_CYCLES' undeclared here in old Linux kernels (perf plugin) * Fixed invalid XML page error (tomcat plugin) * Remove obsolete monit metrics * Fixed Failed to parse error in adaptec_raid * Fixed cluster_health_nodes and cluster_stats_nodes charts in the elasticsearch collector * A modified slave chart's "name" was not properly transferred to the master * Netdata could run out of file descriptors when using the new DB engine * Fixed UI behavior when pressing the End key * Fixed UI link to check the configuration file, to open in a new tab * Prevented Error: 'module' object has no attribute 'Retry' messages from python collectors, by enforcing minimum version check for the UrlService library * Fixed typo that causes nfacct.plugin log messages to incorrectly show freeipmi * The daemon could get stuck during collection or during shutdown, when using the new dbengine. Reduced new dbengine IO utilization by forcing page alignment per dimension of chart. * Properly handle timeouts/no response in dns_query_time python collector * When a collector restarted after having stopped for a long time, the new dbengine would consume a lot of CPU resources. * Fixed error Assertion old_state & PG_CACHE_DESCR_ALLOCATED' failed` of the new dbengine. Eliminated a page cache descriptor race condition * tv.html failed to load the three left charts when accessed via https. Turn tv.html links to https * Change print level from error to info for messages about clearing old files from the database * Fixed warning regarding the x509check_last_collected_secs alarms. Changed the template update frequency to 60s, to match the chart’s update frequency * Email notification header lines were not terminated with \r\n as per the RFC * Some log entries would not be caught by the python web_log plugin. Fixed the regular expressions * Corrected the date used in pushbullet notifications * Fixed FATAL error when using the new dbengine with no direct I/O support, by falling back to buffered I/O * Fixed compatibility issues with varnish v4 (varnish collector) * The total number of disks in mdstat.XX_disks chart was displayed incorrectly. Fixed the "inuse" and "down" disks stacking. * The config option --disable-telemetry was being checked after restarting netdata, which means that we would still send anonymous statistics the first time netdata was started. (NOTE: Telemetry is disabled by default on openSUSE.) * Fixed apcupsd collector errors, by passing correct info to the run function. * apcupsd and libreswan were not enabled by default * Fixed incorrect module name: energi to energid * The nodes view did not work properly when a reverse proxy was configured to access netdata via paths containing subpaths (e.g. myserver/netdata) * Fix error message PLUGINSD : cannot open plugins directory * Corrected invalid links to web_log.conf that appear on the agent UI * Fixed ScaleIO collector endpoint paths * Fixed web client timeout handling in the go.d plugin httpcheck collector
Comments 0